Running a Deployment
This is the main workflow: configure devices, hand them out, collect them, download the data.
If your devices have never been set up, do Getting Started first.
Before you begin
Charge every device fully. A device whose battery is below 3750 mV will not begin recording — it powers off instead and waits. Charging overnight avoids a whole class of confusing failures.
Put every device on a charger while you configure it. Devices are only awake and reachable when plugged in; an unplugged device that is outside its study window powers itself off and will not appear in a scan. This is deliberate — it is what makes the battery last — but it means configuration only happens on the charger.
Know your device IDs. You will pick devices out of a list by the end of their ID; the browser tool shows the last two bytes, such as TotTag 00:02. If you did not label the cases during setup, now is the time.
Install the dashboard
The desktop dashboard is one tool you can use to configure your deployments. Install it with pip,
then run it from any directory:
python3 -m pip install tottag
tottag
There is also a browser-based tool at app.tottag.net. It is a web page, so there is nothing to install, but it needs Chrome, Edge, or Opera on a computer to reach the devices. Both tools configure devices identically and read the same logs; use whichever suits you.
Step 1 — Schedule the deployment
With every device on a charger:
- Scan for TotTags. Devices appear by ID. Wait until all of them are listed — a device that has just been plugged in can take a few seconds to show up.
- Schedule New Pilot Deployment, without connecting to any device. The dashboard connects to every device in the study itself; if you are already connected to a device, the button updates only that device.
-
Fill in:
Field Meaning Deployment Timezone The time zone the study happens in. Every time you enter uses this clock, and changing it reinterprets the times already entered. Start / End Date and Time The outer bounds of the study. Nothing is recorded before the start or after the end. Daily Start / End Time Optional. Restricts recording to a window within each day, in the study’s local time: school hours, say. Leave unset to record continuously between the start and end dates. TotTags in Deployment The devices taking part. Maximum 10. - Schedule. The configuration is pushed to every device on the list, and read back over either USB or Bluetooth to confirm that each one stored it successfully.
- Save the deployment record when the dashboard asks. Keep it in the folder you will download the logs to: it is the only place the study’s time zone is kept, and both tools read from it to show times, charts, and daily figures in the correct time zone.
A few things worth understanding:
- The time zone is the study’s, not yours. Pick the time zone where the devices will be deployed, even if you are configuring them from somewhere else, and enter every time as a clock on the wall there would show it.
- If the clocks change during the study, a device cannot follow the change, so its daily window moves by an hour on one side of it. The browser tool points this out and asks which side should keep the hours you entered, or whether to widen the window to cover both.
- Daily windows may cross midnight. A daily window of 22:00 to 06:00 is understood as overnight, not as an error.
- Every device must be scheduled. A device that was not on the charger when you pressed Schedule does not know about the study and will not take part. Scan again and confirm the list.
Afterwards, Connect to a device and use Get Scheduled Deployment Details to read back what it actually stored.
In the browser tool
On Set up a deployment, give the study a name if you like, choose its time zone, dates, and daily hours, then Add a tag for each device. As each one is added, the page reads its battery, its clock, and any deployment it still holds, and the summary beside the form lists anything that needs attention before writing. Write to tags writes each device in turn and reads it back, so every device is checked, not just one. Save the deployment record it produces: it lists exactly what each device confirmed it stored, with times in the study’s time zone. Keep it with the logs, for the same reason as above.
Before you schedule over an earlier study
Scheduling a device starts a fresh log. Nothing is erased from the device’s memory, but whatever it recorded for the previous study can no longer be downloaded with either tool. Download every device from the previous study first (Step 4). The browser tool knows which studies’ data it has saved, and will not write over one it has not seen saved unless you verify that the data is safe elsewhere.
Step 2 — Hand out the devices
Take them off the chargers.
Each device plays a sound as it comes off the charger, and from that moment behaves as follows:
- Inside the study window — it starts ranging and recording.
- Before the study starts — it powers off and wakes itself at the start time.
- Outside a daily window — it powers off and wakes at the next daily start.
- Battery too low — it powers off and waits for a charger.
Devices find each other automatically. There is no pairing step and no fixed roles — the network forms itself, and reforms if devices are separated and brought back together.
Charge devices overnight, not during study hours. A device on its charger does not range, so nothing is recorded while it is plugged in; taken off the charger, it starts again as described above. Overnight charging is part of any multi-day study. Leaving a device on its charger during study hours is the most common way to lose data.
Step 3 — During the study
Nothing is required. There is no live upload and no server; the data sits on each device.
Two things are available if you need them, both requiring the device in hand:
- Subscribe to Live Ranging Data shows distances in real time. The device must be off its charger for this, since it has to be ranging.
- Activate Find my TotTag makes a device chirp so you can find it.
Step 4 — Collect and download
Put each device back on its charger — this both stops recording and is required for downloading.
In the dashboard: Connect to a device, then choose a download:
| Action | What you get |
|---|---|
| Download Deployment Log Files | Everything recorded during the scheduled study. This is normally what you want. |
| Download Full Logs | The whole of the current log, ignoring the study’s dates: everything recorded since the device was last scheduled or canceled. Earlier studies cannot be downloaded. |
Downloads take minutes rather than seconds and produce a .ttg file per device, plus a processed
.pkl alongside it; the browser tool saves only the .ttg file. See Your Data for
what is inside.
Watch the console while it downloads
Occasionally a page of the log does not survive the transfer. The tool notices, asks the device to resend, and tells you what it is doing:
Requesting 7 of 7 missing page(s), round 1...
That is normal and self-correcting. What is not normal is a message like:
WARNING: log from 31 is incomplete:
transfer ended early: 8 of 10 pages received
If you see that, download the device again before wiping anything. The data is still on the device. A second attempt usually succeeds. See Troubleshooting.
Step 5 — Check what you got before reusing the devices
Downloading is the last moment when a problem is still fixable. Before you clear devices for the next study, confirm that each log:
- covers the dates you expect;
- contains all the devices you expect, each seeing the others;
- has no warnings left unresolved from the download.
Your Data shows how to check each of these, and the browser tool’s What happened tab shows them all at once. Ten minutes here saves a study.
Canceling or changing a deployment
Connect to a device and use Cancel Deployment On Current Device to clear its schedule. Each device must be canceled individually, on its charger. This is only necessary if you want to cancel a deployment that has not yet occurred or has started but not yet ended. This is not necessary for simply storing or reusing the devices in a new study.
To change a study’s times or membership, schedule again; canceling first is not necessary.
Neither canceling nor scheduling erases a device’s memory, but both start a fresh log: anything the device recorded before can no longer be downloaded with either tool. Download it first. In the browser tool, canceling is on the Check a tag page, which says whether the device’s data has been saved before it asks you to confirm.